Özet
INTRODUCTION: A nationwide multicentre study was conducted to establish well-defined reference intervals (RIs) of haematological parameters for the Turkish population in consideration of sources of variation in reference values (RVs). MATERIALS AND METHODS: K2-EDTA whole blood samples (total of 3363) were collected from 12 laboratories. Sera were also collected for measurements of iron, UIBC, TIBC, and ferritin for use in the latent abnormal values exclusion (LAVE) method. The blood samples were analysed within 2 hours in each laboratory using Cell Dyn and Ruby (Abbott), LH780 (Beckman Coulter), or XT-2000i (Sysmex). A panel of freshly prepared blood from 40 healthy volunteers was measured in common to assess any analyser-dependent bias in the measurements. The SD ratio (SDR) based on ANOVA was used to judge the need for partitioning RVs. RIs were computed by the parametric method with/without applying the LAVE method. RESULTS: Analyser-dependent bias was found for basophils (Bas), MCHC, RDW and MPV from the panel test results and thus those RIs were derived for each manufacturer. RIs were determined from all volunteers' results for WBC, neutrophils, lymphocytes, monocytes, eosinophils, MCV, MCH and platelets. Gender-specific RIs were required for RBC, haemoglobin, haematocrit, iron, UIBC and ferritin. Region-specific RIs were required for RBC, haemoglobin, haematocrit, UIBC, and TIBC. CONCLUSIONS: With the novel use of a freshly prepared blood panel, manufacturer-specific RIs' were derived for Bas, Bas%, MCHC, RDW and MPV. Regional differences in RIs were observed among the 7 regions of Turkey, which may be attributed to nutritional or environmental factors, including altitude.
Konular
Atıflar
OpenAlex cited_by_count. WoS veya Scopus atıf sayısı değildir; o kaynaklar için ayrı kolon yoktur.
27atıfOpenAlex · cited_by_count (önbellek / veritabanı)
Yerel katalogda bu makaleye atıf yapan 9 yayın (OpenAlex referans eşleşmesi; tam dünya listesi değildir).
- 2018 Comparison of Calculation Methods and Evaluationof Procedures for Merging Reference MeasurementsFrom Two US Medical CentersAtıf 16 · OpenAlex
- 2024 Neutropenia and Hematology AnalyzerAtıf 0 · OpenAlex
- 2022 THE RELATIONSHIP BETWEEN BLOOD GROUPS AND PLATELETCRIT IN HEALTHY TURKISH POPULATIONAtıf 0 · OpenAlex
- 2022 The Relatıonshıp Between Blood Groups And Plateletcrıt In Healthy Turkısh PopulatıonAtıf 0 · OpenAlex
- 2022 Correlation of Plateletcrit According to Blood Groups in Healthy Turkish PopulationAtıf 0 · OpenAlex
- 2021 Saline replacement as a practical solution to matrix interference effect when a leukocyte differential count cannot be measured in chemotherapy patient samplesAtıf 0 · OpenAlex
- 2021 Saline replacement as a practical solution to matrix interference effect when a leukocyte differential count cannot be measured in chemotherapy patient samplesAtıf 0 · OpenAlex
- 2021 A practical solution of matrix interference effect with saline replacement in samples of chemotherapy received patients whose differential count of leukocyte cannot be measuredAtıf 0 · OpenAlex
- 2021 Saline replacement as a practical solution to matrix interference effect when a leukocyte differential count cannot be measured in chemotherapy patient samplesAtıf 0 · OpenAlex