Quantitative measurements obtained by micro computed tomography andconfocal laser scanning microscopy

Dergi DENTOMAXILLOFACIAL RADIOLOGY
YÖKSİS OpenAlex Açık erişim · green
Yıl2008
Atıf20OpenAlex
Atıf21Semantic Scholar · 2 etkili
Yüzdelik%75,5
FWCI0,881,00 = dünya ortalaması
Scopus (SJR)Q1

Veri kaynağı ayrımı

  • YÖKSİSYÖKSİS makale kaydı
  • YÖKSİS dergi adıDENTOMAXILLOFACIAL RADIOLOGY
  • OpenAlexOpenAlex zenginleştirmesi (özet, atıf, konular)
  • Semantic Scholaratıf sayısı (OpenAlex ile birleştirilmez)

Özet

OpenAlex İngilizce

OBJECTIVES: To compare measurements obtained by micro-CT with those obtained by confocal laser scanning microscope in simulative internal resorption cavities. METHODS: An extracted human maxillary central incisor tooth was divided into two in the coronal plane. Four artificial internal resorption cavities were prepared with standardized burs on each section, and diameters and volumes were measured using a laser scanning electron confocal microscope and a desktop cone beam micro-CT-40. Differences between means of quantitative measurements for both methods were tested using the paired t-test; the correlation between quantitative measurements was tested by regression analysis. RESULTS: Mean diameter and volume differences between the two methods were 0.061 mm and 0.004 mm(3), respectively. Average diameter and volume calculations obtained by micro-CT were significantly lower (P < 0.001 for diameter and P < 0.01 for volume). A significantly strong relationship was found in the average diameters (R(2) = 92.9%) and calculated volumes (R(2) = 91%), (P < 0.001). CONCLUSIONS: Although a strong correlation between both methods was found, micro-CT significantly underestimated the diameters and volumes.

Konular

Atıflar

OpenAlex cited_by_count. WoS veya Scopus atıf sayısı değildir; o kaynaklar için ayrı kolon yoktur.

20atıfOpenAlex · cited_by_count (önbellek / veritabanı)

Yerel katalogda bu makaleye atıf yapan 15 yayın (OpenAlex referans eşleşmesi; tam dünya listesi değildir).

  1. 2010 A comparison of the diagnostic accuracy of CBCT images of different voxel resolutions used to detect simulated small internal resorption cavitiesAtıf 117 · OpenAlex
  2. 2010 A comparison of the diagnostic accuracy of CBCT images of different voxel resolutions used to detect simulated small internal resorption cavitiesAtıf 117 · OpenAlex
  3. 2011 Observer Ability to Detect Ex Vivo Simulated Internal or External Cervical Root ResorptionAtıf 89 · OpenAlex
  4. 2011 Observer Ability to Detect Ex Vivo Simulated Internal or External Cervical Root ResorptionAtıf 88 · OpenAlex
  5. 2015 Comparison of micro computerized tomography and cone beam computerized tomography in the detection of accessory canals in primary molarsAtıf 72 · OpenAlex
  6. 2015 Comparison of micro-computerized tomography and cone-beam computerized tomography in the detection of accessory canals in primary molarsAtıf 72 · OpenAlex
  7. 2015 Comparison of micro-computerized tomography and cone-beam computerized tomography in the detection of accessory canals in primary molarsAtıf 72 · OpenAlex
  8. 2015 Comparison of micro computerized tomography and cone beam computerized tomography in the detection of accessory canals in primary molarsAtıf 72 · OpenAlex
  9. 2018 Evaluation of 3 Different Retreatment Techniques in Maxillary Molar Teeth by Using Micro–computed TomographyAtıf 55 · OpenAlex
  10. 2018 EVALUATION OF 3 DIFFERENT RETREATMENT TECHNIQUES IN MAXILLARY MOLAR TEETH BY USING MICRO–COMPUTED TOMOGRAPHYAtıf 55 · OpenAlex

Yazarlar

5
  1. Kamburoglu K. 1
  2. Barenboim S. F. 2
  3. Arituerk T. 3
  4. Kaffe I. 4
  5. KIVANÇ KAMBUROĞLU ANKARA ÜNİVERSİTESİ 5