İçeriğe geç
akaturk Akademik ölçüm

Makale detayı · 2019 · article

Radiation exposure and patient organ dose measurement from 18F-FDG in a PET/CT facility

Dergi Pakistan Journal of Nuclear Medicine
ISSN2221-0288
YÖKSİS OpenAlex
Yıl2019
Atıf1OpenAlex
Yüzdelik%60,0
FWCI0,181,00 = dünya ortalaması

Veri kaynağı ayrımı

  • YÖKSİSYÖKSİS makale kaydı
  • YÖKSİS dergi adıPakistan Journal of Nuclear Medicine
  • OpenAlexOpenAlex zenginleştirmesi (özet, atıf, konular)
  • Semantic Scholaratıf sayısı (OpenAlex ile birleştirilmez)

Özet

OpenAlex İngilizce

Background: 18F-fluorodeoxyglucose (FDG) is a radiopharmaceutical (radioactive tracer), generally used in the medical indicator on positron emission tomography/computerized tomography (PET/CT). PET/CT is an essential device for patients’ diagnosis and their responses to treatment; it uses radioactive tracers for diagnosis. PET/CT is used with a special detector and worked with a computer to evaluate the sick organ and the functions of the tissues. PET/CT scanning is a special type of nuclear medicine indicator, highly used in clinics. In this study, we aimed to measure the level of radiation and its effectiveness in mentioned organs in PET/ CT devices. In the basis of this study, we want to reveal the level of radiation in different age range of patient’s absorbed organ 18F-FDG. Methods: The absorbed organ’s radiation level and the affected organ’s radiation level were calculated in accordance with Monte Carlo (MC) methods. Results: The results for the patient’s target organs in the used phantoms showed variations in age stages when compared with those determined by the MC simulation. These variances result from the structural anatomical differences in the age studied and in significant changes in the relation to their activity rate. Conclusion: The medical radiation which is exposed from PET/CT studies should be important in all the patients groups, furthermore, is more considerable in pediatric and adolescence patients. The As Low As Reasonably Achievable principle must be implemented in either by reducing the radiation dose on PET/CT or by considering alternative diagnostic imaging unit or device should be used.

Konular

Atıflar

OpenAlex cited_by_count. WoS veya Scopus atıf sayısı değildir; o kaynaklar için ayrı kolon yoktur.

1atıfOpenAlex · cited_by_count (önbellek / veritabanı)

Yerel katalogda bu makaleye atıf yapan 2 yayın (OpenAlex referans eşleşmesi; tam dünya listesi değildir).

  1. 2018 Radiation exposure and patient organ dose measurement from 18F-FDG in a PET/CT facilityAtıf 1 · OpenAlex

Yazarlar

2
  1. MEHMET ERDOĞAN SÜLEYMAN DEMİREL ÜNİVERSİTESİ 1
  2. ÜMİT KARA 2