İçeriğe geç
akaturk Akademik ölçüm

Makale detayı · 2018 · article

The Effect of Hot-Cold Applications on Patellar Tendon to Torque-Time Parameters

Dergi Turkish Journal of Sports Medicine
ISSN1300-0551
YÖKSİS OpenAlex Açık erişim · diamond
Yıl2018
Atıf1OpenAlex
Yüzdelik%11,5
FWCI0,01,00 = dünya ortalaması

Veri kaynağı ayrımı

  • YÖKSİSYÖKSİS makale kaydı
  • YÖKSİS dergi adıTurkish Journal of Sports Medicine
  • OpenAlexOpenAlex zenginleştirmesi (özet, atıf, konular)
  • Semantic Scholaratıf sayısı (OpenAlex ile birleştirilmez)

Özet

OpenAlex İngilizce

Objective: Therapeutic use of thermal agents such as hot-cold is common in clinical practice and rehabilitation applications.Changes in tissue temperature create a therapeutic effect by making alterations in metabolism, neurotransmission, hemodynamics and mechanical properties.In this study, the effects of hot-cold applications on patellar tendon to torque-time parameters were investigated.Materials and Methods: 30 healthy individuals (16 males, 14 females) at the age of 18-30 years were participated to the study.Participants' demographic characteristics were recorded, body weight and height measurements were performed, and Tegner activity scores were noted.Hot and cold applications have been applied to the participants with 48 hours of interval.Following 5 minutes of submaximal warming exercise in cycle ergometer, patellar tendon temperatures were measured with infrared thermometer and thermal camera.Isokinetic strength tests (concentric mode at 60°/second and 180°/second) were performed.Hot or cold applications were performed on patellar tendon for 30 minutes.The submaximal warmup exercise repeated following the application, temperature measurements and isokinetic tests were performed again.All tests were performed on dominant lower extremity of the participants.Results: Statistically significant results were obtained both at infrared thermometer (p<0.001) and also at thermal camera measurements (p<0.001) in the pre-post cooling and heating temperature evaluations.Time to peak torque and rate of peak torque development were similar in pre and post cold measurements (p >0.05), whereas time to peak torque was significantly lower (p<0.05)and significant increase in rate of peak torque development (p<0.01) has been determined following hot application. Conclusion:Heat application on patellar tendon may improve athletic performances that require explosive force.There is need for more comprehensive studies to validate the findings obtained by this study.

Konular

Atıflar

OpenAlex cited_by_count. WoS veya Scopus atıf sayısı değildir; o kaynaklar için ayrı kolon yoktur.

1atıfOpenAlex · cited_by_count (önbellek / veritabanı)

Yerel katalogda bu makaleye atıf yapan 2 yayın (OpenAlex referans eşleşmesi; tam dünya listesi değildir).

  1. 2025 The Effects of Cold and Hot Applications on Knee Joint Laxity and Post-Jump Landing Biomechanics in Healthy IndividualsAtıf 0 · OpenAlex
  2. 2024 The Effects of Cold and Hot Applications on Knee Joint Laxity and Post-Jump Landing Biomechanics in Healthy IndividualsAtıf 0 · OpenAlex

Yazarlar

5
  1. YURDAGÜL BAYGÜL 1
  2. ABDULLAH MERİÇ ÜNAL BURDUR MEHMET AKİF ERSOY ÜNİVERSİTESİ 2
  3. AHSEN OĞUL 3
  4. SABRİYE ERCAN SÜLEYMAN DEMİREL ÜNİVERSİTESİ 4
  5. CEM ÇETİN SÜLEYMAN DEMİREL ÜNİVERSİTESİ 5