İçeriğe geç
akaturk Akademik ölçüm

Makale detayı · 2019 · article

Experimental study of influence of composition on radiopacity of fiber post materials

ISSN1059-910X
YÖKSİS OpenAlex
Yıl2019
Atıf5OpenAlex
Yüzdelik%64,3
FWCI0,711,00 = dünya ortalaması
Scopus (SJR)Q2
WoS (JCR)Q1

Veri kaynağı ayrımı

  • YÖKSİSYÖKSİS makale kaydı
  • YÖKSİS dergi adıMicroscopy Research and Technique
  • Katalog eşleşmesi (ISSN)Microscopy Research and Technique
  • OpenAlexOpenAlex zenginleştirmesi (özet, atıf, konular)
  • Semantic Scholaratıf sayısı (OpenAlex ile birleştirilmez)

Özet

OpenAlex İngilizce

This experimental study aims to evaluate the radiopacity of various fiber post materials and to determine the effects of material composition as analyzed by energy-dispersive X-ray spectrophotometry (EDS; EDAX Team Software; EDAX, Inc., Mahwah, NJ) on radiopacity. Five specimens of seven fiber post materials with 2-mm thickness were prepared and digital radiographs were taken with an aluminum stepwedge (SW) and 2-mm-thick tooth slice. The mean gray values (MGVs) of specimens were measured using the histogram function of a computer graphics program (Adobe Photoshop CS6; Adobe System, Inc., San Jose, CA). The MGVs of fiber post materials were compared with an aluminum SW and dentin of equal thickness. The fiber post specimens were examined by scanning electron microscopy and EDS analysis performed for the elementary analysis of material composition. The MGVs of fiber posts ranged between 83.67 ± 3.64 and 57.80 ± 7.08 pixels. Materials were sorted in descending order of MGV as follows: Reforpost, Carbopost, D.T. Light-Post, Easypost, Glassix Radiopaque, Dentolic Glass Fiber Post, and RelyX Fiber Post. All fiber posts demonstrated significantly higher radiopacity values than 2-mm-thick aluminum (p < .05). EDS analysis results indicated that the evaluated fiber posts included various elements for radiopacity in different ratios. All tested fiber post materials showed radiopacity values above the minimum recommendations of the International Organization for Standardization. EDS analysis results indicated that each manufacturer used different compositions of elements like zirconium, barium, titanium, and iron for achieving radiopacity in materials.

Konular

Atıflar

OpenAlex cited_by_count. WoS veya Scopus atıf sayısı değildir; o kaynaklar için ayrı kolon yoktur.

5atıfOpenAlex · cited_by_count (önbellek / veritabanı)

Yerel katalogda bu makaleye atıf yapan 8 yayın (OpenAlex referans eşleşmesi; tam dünya listesi değildir).

  1. 2021 Energy-Dispersive X-Ray Spectrometry Analysis and Radiopacity of Five Different Root Canal Sealers.Atıf 7 · OpenAlex
  2. 2021 Energy-Dispersive X-Ray Spectrometry Analysis and Radiopacity of Five Different Root Canal SealersAtıf 7 · OpenAlex
  3. 2021 Energy-dispersive x-ray spectrometry analysis and radiopacity of five different root canal sealersAtıf 7 · OpenAlex
  4. 2021 Energy-Dispersive X-Ray Spectrometry Analysis and Radiopacity of Five Different Root Canal SealersAtıf 7 · OpenAlex
  5. 2021 Energy-Dispersive X-Ray Spectrometry Analysis and Radiopacity of Five Different Root Canal SealersAtıf 7 · OpenAlex
  6. 2022 Comparative Evaluation of Artifacts Originated by Four Different Post Materials Using Different CBCT SettingsAtıf 5 · OpenAlex
  7. 2022 Comparative Evaluation of Artifacts Originated by Four Different Post Materials Using Different CBCT SettingsAtıf 5 · OpenAlex
  8. 2025 Noise-optimized cone-beam computed tomographic imaging of different post materials with multiple settings: A comparative analysisAtıf 0 · OpenAlex

Yazarlar

3
  1. AYŞE AYDOĞMUŞ ERİK 1
  2. CEVAT EMRE ERİK 2
  3. DERYA YILDIRIM SÜLEYMAN DEMİREL ÜNİVERSİTESİ 3