İçeriğe geç
akaturk Akademik ölçüm

Makale detayı · 2026

Collapse prevention limit states for substandard RC shear walls using a novel bond-slip-based steel model

Bulletin of Earthquake Engineering

YÖKSİS OpenAlex Açık erişim · hybrid SJR Q1 JCR Q1 Atıf 0 Yüzdelik 22.9% FWCI 0.0
Yıl
2026
ISSN
1570-761X
Tür
article

Veri kaynağı ayrımı

  • YÖKSİS YÖKSİS makale kaydı
  • OpenAlex OpenAlex zenginleştirmesi (özet, atıf, konular)

Özet

İngilizce (OpenAlex)

Reinforced concrete shear walls constructed before modern earthquake codes pose significant risks under earthquake loads due to the use of smooth reinforcement bars, inadequate embedment lengths, and low-strength concrete. In such substandard systems, rapid deterioration of the steel–concrete bond pushes the pre-collapse limit states to an earlier stage beyond current code predictions. However, modern earthquake codes such as TBEC, fib2010 and ASCE/SEI41 use calibrated equations for deformed/ribbed reinforcements and idealized bond conditions, which conflicts with realistic performance evaluation of these systems. In this study, based on experimental data, a new pseudo-steel material model is proposed and implemented in a numerical framework to simulate both elastic-plastic behavior and bond-slip effects of smooth bars in substandard shear walls. The model includes empirical reduction factors for elastic stiffness, post-yield hardening, and yield strength to realistically captures slip failure mode by directly integrating bond loss into the steel stress-strain relationship. The numerical models reproduced moment–chord rotation envelopes of tested specimens with high accuracy. Additionally, collapse prevention limits defined in modern codes were compared against experimental and numerical results showing that all codes significantly over-predicted the ultimate chord rotation for substandard shear walls. These deviations are primarily due to the idealized assumptions of the codes such as steel post-hardening, confined concrete strength, and overvaluation of post-yield rotations. Therefore, this study proposes a modification to the collapse prevention formulation in the Turkish code to match the actual behavior of substandard shear walls. The proposal redefines the plastic hinge length as one-third of the wall length, and adding a correction term reflecting plastic reinforcement slip. The revised formulation limited the prediction of the ultimate chord rotation to a more realistic value of 1%, offering a more reliable framework for assessing the seismic performance of existing nonconforming reinforced concrete shear walls.

Konular

  • Seismic Performance and Analysis
  • Structural Response to Dynamic Loads
  • Structural Behavior of Reinforced Concrete

Birincil konu Seismic Performance and Analysis

Yazarlar

  1. MUHAMMED NADİR OLABİ
  2. GÖKHAN DOK SAKARYA UYGULAMALI BİLİMLER ÜNİVERSİTESİ
  3. NACİ ÇAĞLAR SAKARYA ÜNİVERSİTESİ