Makale detayı · 2007

Determination of trace amounts of copper in tap water samples with a calix 4 arene modified carbon paste electrode by differential pulse anodic stripping voltammetry

Electroanalysis

YÖKSİS OpenAlex SJR Q2 JCR Q1 Atıf 42 Yüzdelik 85.4% FWCI 2.22
Yıl
2007
ISSN
1040-0397
Tür
article

Veri kaynağı ayrımı

  • YÖKSİS YÖKSİS makale kaydı
  • OpenAlex OpenAlex zenginleştirmesi (özet, atıf, konular)

Özet

İngilizce (OpenAlex)

Abstract A calix[4]arene modified carbon paste electrode was used for trace determination of copper. The study of the preconcentration of copper as well as the other heavy metal ions at the modified electrode, with subsequent measurement by differential pulse anodic stripping voltammetry (DPASV), indicates the efficient open‐circuit accumulation of the analytes onto the electrode. Many parameters such as the composition of the paste, pH, preconcentration time and stirring rate influence the response of the measurement. The procedure was optimized for copper determination. For a 10‐minute preconcentration time at pH 6.5–7.5, the detection limit (LOD) was 1.1 μg L−1. The optimized method was successfully applied to the determination of copper in tap water sample by means of standard addition procedure. The copper content of the sample was comparable with the result obtained with AAS method.

Konular

  • Electrochemical Analysis and Applications
  • Analytical Chemistry and Sensors
  • Electrochemical sensors and biosensors

Birincil konu Electrochemical Analysis and Applications