QT Dispersion Significantly Increases after Implantable Cardioverter-Defibrillator Shocks

Annals of Noninvasive Electrocardiology

YÖKSİS OpenAlex Açık erişim · bronze SJR Q2 Atıf 7 Yüzdelik 15.7% FWCI 0.0
Yıl
2007
ISSN
1082-720X
Tür
article

Veri kaynağı ayrımı

  • YÖKSİS YÖKSİS makale kaydı
  • OpenAlex OpenAlex zenginleştirmesi (özet, atıf, konular)

Özet

İngilizce (OpenAlex)

OBJECTIVE: To determine whether QT dispersion (QTd), a noninvasive electrocardiographic parameter of ventricular tachyarrhythmia risk assessment, is changed by implantable cardioverter-defibrillator (ICD) shocks delivered during implantation process, to analyze the duration of these changes, and to further evaluate the effect of amiodarone on these parameters. METHODS: Twenty-six consecutive patients who are scheduled to undergo ICD implantation for aborted sudden cardiac death or documented symptomatic sustained ventricular tachycardia were enrolled into the study. A simultaneous 12-lead electrocardiogram (ECG) was recorded after the ICD implantation just before starting the testing shock when the patients were under general anesthesia (baseline record) and at 1st, 5th, 10th, 15th, 20th, 25th, and 30th minutes after the successful shocks. RR interval, QT interval, corrected QT interval (QTc), QTd, and corrected QTd (QTcd) were all measured and calculated on ECG. RESULTS: At 1st minute after the successful shock, an abrupt increase (from 67.0 +/- 13.8 ms to 94.8+/-21 ms, P < 0.0001) was observed in QTcd, which was followed by a gradual return to the preshock values at 20th minute. Analysis of patients with and without long-term oral amiodarone treatment showed that in amiodarone-pretreated patients QTcd returned to the baseline value earlier than in patients without amiodarone treatment (15 minutes vs 20 minutes, respectively). CONCLUSIONS: ICD shocks cause an increase in QTcd lasting for up to 20th minute, which may predominate in some important clinical problems like electrical storm. Amiodarone, with the desirable effect on QTcd, may reduce the proarrhythmic effects of ICD shocks.

Konular

  • Cardiac electrophysiology and arrhythmias
  • ECG Monitoring and Analysis
  • Cardiac Arrhythmias and Treatments

Birincil konu Cardiac electrophysiology and arrhythmias

Yazarlar

  1. SERKAN TOPALOĞLU
  2. DURSUN ARAS
  3. ONUR ŞAHİN
  4. ERGUN KUMRAL
  5. BÜLENT DEVECİ
  6. ÖZCAN ÖZDEMİR
  7. ÖZCAN ÖZEKE
  8. ALİ YILDIZ
  9. ÖMER ALYAN İSTANBUL MEDİPOL ÜNİVERSİTESİ
  10. AHMET DURAN DEMİR
  11. MUSTAFA ÖZCAN SOYLU
  12. HALİL LÜTFİ KISACIK BALIKESİR ÜNİVERSİTESİ
  13. FATMA ŞULE KORKMAZ