İçeriğe geç
akaturk Akademik ölçüm

Makale detayı · 2022 · article

Diagnostic Performance Evaluation of Complete Urinalysis in the Diagnosis of Urinary Tract Infection

Dergi Chronicles of Precision Medical Researchers
ISSN2757-6124
YÖKSİS OpenAlex Açık erişim · green
Yıl2022
Atıf3OpenAlex
Yüzdelik%55,4
FWCI0,291,00 = dünya ortalaması

Veri kaynağı ayrımı

  • YÖKSİSYÖKSİS makale kaydı
  • YÖKSİS dergi adıChronicles of Precision Medical Researchers
  • OpenAlexOpenAlex zenginleştirmesi (özet, atıf, konular)

Özet

OpenAlex İngilizce

Aim: The aim was to evaluate the adequacy of the diagnostic performance of urinalysis parameters in the diagnosis of urinary tract infection. Materials and Methods: In this retrospective study, the results of 13,315 individuals who had urine culture and complete urinalysis were analyzed. Midstream urine culture results were taken as a reference in the diagnosis of urinary tract infections. The diagnostic performance of urinalysis’ chemical parameters [appearance, leukocyte esterase(LE), nitrite] and microscopic parameters (bacteria and squamous epithelium) individually and in combination were evaluated. Two different cut-off values (trace and 1+) were used while performing the analysis. Sensitivity, specificity, positive predictive value, negative predictive value, and likelihood ratios were calculated. The area under the curve (AUC) was evaluated with receiver operating curve (ROC) analysis. Results: Of the samples, 10.1% were evaluated as culture positive. The highest sensitivity rate was observed in the combination of the presence of any of the LE (trace), nitrite (trace), and bacteria parameters (86%). When evaluated as a single parameter, the highest sensitivity was observed in the LE(trace) parameter (81.6%). The negative predictive value was >90% in both single-parameter and combination evaluations. The AUC of the LE and nitrite tests was calculated as 0.758 and 0.718, respectively. Conclusion: The parameters evaluated in this study, singly or in combination, showed sufficient performance in predicting negative urine cultures. Although complete urinalysis analyses cannot replace culture examinations, we believe that they can reduce unnecessary culture examinations.

Konular

Atıflar

OpenAlex cited_by_count. WoS veya Scopus atıf sayısı değildir; o kaynaklar için ayrı kolon yoktur.

3atıfOpenAlex · cited_by_count (önbellek / veritabanı)

Yerel katalogda bu makaleye atıf yapan 7 yayın (OpenAlex referans eşleşmesi; tam dünya listesi değildir).

  1. 2024 YOLOv5 based detector for eight different urine particles components on single board computerAtıf 6 · OpenAlex
  2. 2024 YOLOv5 based detector for eight different urine particles components on single board computerAtıf 6 · OpenAlex
  3. 2023 YOLOv5 based detector for eight different urine particles components on single board computerAtıf 6 · OpenAlex
  4. 2024 Deep Multi-Modal Fusion Model for Identification of Eight Different Particles in Urinary SedimentAtıf 2 · OpenAlex
  5. 2024 Deep Multi-Modal Fusion Model for Identification of Eight Different Particles in Urinary SedimentAtıf 2 · OpenAlex
  6. 2024 Deep Multi-Modal Fusion Model for Identification of Eight Different Particles in Urinary SedimentAtıf 2 · OpenAlex
  7. 2026 Urinary tract infections in home health care patients: microbiological profile and antimicrobial resistanceAtıf 0 · OpenAlex

Yazarlar

7
  1. TUBA ARPAĞ BATUR 1
  2. ERDEM ÇOKLUK 2
  3. SÜMEYYE AKYÜZ 3
  4. BÜNYAMİN UÇAR 4
  5. HAMİT HAKAN ALP VAN YÜZÜNCÜ YIL ÜNİVERSİTESİ 5
  6. ZÜBEYİR HUYUT 6
  7. AYŞE ÖZKAÇMAZ VAN YÜZÜNCÜ YIL ÜNİVERSİTESİ 7