İçeriğe geç
akaturk Akademik ölçüm

Makale detayı · 2025

Ultrasound-Assisted Sustainable Processing of Garden Cress Juice: Enhancing Bioactive Compounds and Bioaccessibility through XGBoost Optimization

Dergi

ACS Omega

ISSN 2470-1343

YÖKSİS OpenAlex Açık erişim · gold SJR Q1 JCR Q2 Atıf 4 Yüzdelik 88.6% FWCI 2.33
Yıl
2025
Tür
article

Veri kaynağı ayrımı

  • YÖKSİS YÖKSİS makale kaydı
  • YÖKSİS dergi adı ACS Omega
  • Katalog eşleşmesi (ISSN) ACS Omega
  • OpenAlex OpenAlex zenginleştirmesi (özet, atıf, konular)

Özet

OpenAlex · İngilizce

High Resolution Image Download MS PowerPoint Slide This study aimed to improve the functional and nutritional properties of garden cress ( Lepidium sativum ) juice using ultrasound and optimize process parameters by modeling them with advanced machine learning algorithms. Using a Box–Behnken experimental design, the effects of sonication time (8–16 min) and amplitude (60–100%) on total chlorophyll, total phenolic content (TPC), and ferric reducing antioxidant power (FRAP) were investigated. Nonparametric, high-accuracy estimations were made using the XGBoost algorithm. Optimum conditions were determined to be 12 min and 80% amplitude. Under these conditions, TPC (78.44 mg GAE/mL), FRAP (59.80 mg TE/mL), and chlorophyll (7.15 g/100 mL) values were significantly higher than those in control and pasteurized samples ( p < 0.05). HPLC-DAD analysis showed that ultrasound treatment positively impacted the phenolic profile by increasing the release of quercetin, quercetin derivatives, caffeic acid, and chrysin. GC-MS data revealed that volatile aroma compounds (especially 1-hexanol, benzaldehyde, and cinnamaldehyde) were preserved mainly by ultrasound. In vitro digestion simulation showed that total postdigestion recovery rates in ultrasound-treated samples were 34.96% for TPC, 32.50% for chlorophyll, and 28.81% for FRAP, demonstrating a significant increase in bioaccessibility. PCA and hierarchical clustering analyses confirmed a significant biochemical separation of ultrasound-treated samples. The findings indicate that ultrasound technology is a superior method for preserving bioactive compounds, maintaining the aroma profile, and enhancing bioaccessibility compared to heat treatment. This enables data-driven process design. The developed model showed a strong predictive performance under optimal conditions. However, the study is limited by the relatively small data set used for model training.

Konular

Atıflar

OpenAlex cited_by_count. WoS veya Scopus atıf sayısı değildir; o kaynaklar için ayrı kolon yoktur.

4 atıf

OpenAlex cited_by_count (önbellek / veritabanı)

Yazarlar

  1. OKAN LEVENT
  2. MEHMET ALİ ŞİMŞEK
  3. SEYDİ YIKMIŞ TEKİRDAĞ NAMIK KEMAL ÜNİVERSİTESİ
  4. SELİNAY DEMİREL
  5. NAZAN TOKATLI DEMİROK TEKİRDAĞ NAMIK KEMAL ÜNİVERSİTESİ
  6. MELİKENUR TÜRKOL
  7. Moneera O. Aljobair
  8. NAZLI TOKATLI İSTANBUL SAĞLIK VE TEKNOLOJİ ÜNİVERSİTESİ
  9. Isam A. Mohamed Ahmed