The effects of atrium on energy performances of office buildings according to Turkish climate regions

Dergi Journal of Construction Engineering, Management & Innovation (Online)
ISSN2630-5771
YÖKSİS OpenAlex Açık erişim · bronze TR Index
Yıl2019
Atıf4OpenAlex
Yüzdelik%61,0
FWCI0,281,00 = dünya ortalaması
WoS (JCR)Q4

Veri kaynağı ayrımı

  • YÖKSİSYÖKSİS makale kaydı
  • YÖKSİS dergi adıJournal of Construction Engineering, Management & Innovation (Online)
  • OpenAlexOpenAlex zenginleştirmesi (özet, atıf, konular)
  • Semantic Scholaratıf sayısı (OpenAlex ile birleştirilmez)

Özet

OpenAlex İngilizce

Nowadays, the atrium is designed to provide more daylight to the interior and to reduce heating, cooling and total energy loads of buildings.Optimum atrium design can reduce the total energy consumption of a building by reducing artificial lighting loads that greatly affect the heating and cooling energy load.Many parameters are effective in optimum atrium design for building energy performance.These are atrium type, aspect ratio (length to width), height, and preferred glazing types and shading devices on atrium facades.The goal of the study is to assess the impact of these parameters on the building total energy loads and to identify the most energy-efficient atrium design.For this goal, a hypothetical reference office building model is designed.Three office building models were created with the addition of a central courtyard, a central atrium and a semi-closed atrium on the reference office building.It was tested five different double-glazing systems, two window-to-wall ratio, and horizontal louvre shading device on these four office models according to climate regions.All of the models were simulated in DesignBuilder energy simulation software using climatic data of İzmir (hot-humid), Trabzon (moderate-humid) and Ankara (cold) provinces representing primary climatic regions of Turkey.Obtained results were evaluated according to annual heating, cooling and total energy loads according to the climate regions.As a result, the office building model (Model 1) with the central courtyard showed the highest performance in terms of total energy loads in moderate-humid and hot-humid climates.As for the cold climate, Model 3 with semi-closed atrium shows the best performance.

Konular

Atıflar

OpenAlex cited_by_count. WoS veya Scopus atıf sayısı değildir; o kaynaklar için ayrı kolon yoktur.

4atıfOpenAlex · cited_by_count (önbellek / veritabanı)

Yerel katalogda bu makaleye atıf yapan 2 yayın (OpenAlex referans eşleşmesi; tam dünya listesi değildir).

  1. 2023 VENTILATION SOLUTIONS TO THE OVERHEATING PROBLEM IN THE ATRIUM: TRAKYA UNIVERSITY VOCATIONAL SCHOOL OF TECHNICAL SCIENCES BUILDINGAtıf 2 · OpenAlex
  2. 2023 Ventilation Solutions to the Overheating Problem in the Atrium: Trakya University Vocational School of Technical Sciences BuildingAtıf 2 · OpenAlex

Yazarlar

2
  1. SENA GÖKNUR KOÇ ARTVİN ÇORUH ÜNİVERSİTESİ 1
  2. SİBEL MAÇKA KALFA KARADENİZ TEKNİK ÜNİVERSİTESİ 2