Evaluation of the i-STAT analyzer for determination of ionized calcium concentrations in bovine blood
Veri kaynağı ayrımı
- YÖKSİSYÖKSİS makale kaydı
- YÖKSİS dergi adıVETERINARY CLINICAL PATHOLOGY
- Katalog eşleşmesi (ISSN)Veterinary Clinical Pathology
- OpenAlexOpenAlex zenginleştirmesi (özet, atıf, konular)
- Semantic Scholaratıf sayısı (OpenAlex ile birleştirilmez)
Özet
Abstract Background Information regarding the performance of the i‐STAT, a point‐of‐care analyzer, to determine ionized calcium (iCa2+) concentration in bovine blood is limited. Objective The primary goal of this study was to evaluate the agreement of the i‐STAT against a traditional bench‐top blood gas analyzer (Radiometer ABL800 FLEX) in the measurement of iCa2+in the blood of cattle with various disorders. Methods In this study, 121 cattle with various diseases were used. Venous blood samples were run on the i‐STAT and the Radiometer ABL800 FLEX for determination of blood iCa2+concentrations. Data were subjected to Passing‐Bablok regression and Bland‐Altman plots. The Radiometer ABL800 FLEX was the reference method and the i‐STAT was the test method. The i‐STAT performance was evaluated at two different cutoff values for iCa2+concentrations (<1.00 and <1.18 mmol/L) using the receiver operating characteristic curve. Results The Passing‐Bablok regression equation that fit the iCa2+concentration as measured with the i‐STAT (Y) and the Radiometer ABL800 FLEX (X), wasY = −0.108276 [−0.15/−0.06] + 1.103448 [1.06/1.14] × X, with a residual deviation of 0.02. The deviation from the identity line was not significant (P = 0.64). The Bland‐Altman difference plot revealed no bias between the i‐STAT and the Radiometer ABL 800 FLEX. The i‐STAT had a sensitivity of 100% (95% CI, 87.7‐100.0) and 94.8% (95% CI, 87.2‐98.6) at the iCa2+concentration cutoff values of <1.00 and <1.18 mmol/L, respectively. Conclusions iCa2+concentrations in bovine blood measured with the i‐STAT agreed with those of the Radiometer ABL800 FLEX. In particular, the i‐STAT predicted hypocalcemia with a high sensitivity.
Konular
Atıflar
OpenAlex cited_by_count. WoS veya Scopus atıf sayısı değildir; o kaynaklar için ayrı kolon yoktur.
20atıfOpenAlex · cited_by_count (önbellek / veritabanı)
Yerel katalogda bu makaleye atıf yapan 3 yayın (OpenAlex referans eşleşmesi; tam dünya listesi değildir).
- 2023 Validation of a blood gas device for ionized calcium analysis in Holstein cowsAtıf 3 · OpenAlex
- 2023 Validation of a blood gas device for ionized calcium analysis in Holstein cowsAtıf 3 · OpenAlex
- 2023 Validation of a blood gas device for ionized calcium analysis in Holstein CowsAtıf 3 · OpenAlex