İçeriğe geç
akaturk Akademik ölçüm

Makale detayı · 2012

Structural Defects of Existing RC Buildings in Eskisehir Province

Applied Mechanics and Materials

YÖKSİS OpenAlex Açık erişim · hybrid SJR Q4 Atıf 4 Yüzdelik 18.7% FWCI 0.0
Yıl
2012
ISSN
1662-7482
Tür
article

Veri kaynağı ayrımı

  • YÖKSİS YÖKSİS makale kaydı
  • OpenAlex OpenAlex zenginleştirmesi (özet, atıf, konular)

Özet

İngilizce (OpenAlex)

In this study, structural defects of existing 709 reinforced concrete (RC) buildings in Eskisehir Province were represented. Structural defects such as gaps between adjacent buildings, strong beam-weak column, mezzanine floor, short column, corner column, discontinuous frame, anchorage beams, long span, segregation, corrosion, inconvenient column/beam lateral reinforcement, low concrete strength and inconvenient steel reinforcement were determined in the study. It was determined that %35 of existing buildings have discontinuous frame, %16 of them have long span problem. It was also observed that nearly %40 of the buildings have no column/beam lateral reinforcement and %70 of them have inadequate gaps.

Konular

  • Structural Behavior of Reinforced Concrete
  • Structural Load-Bearing Analysis
  • Concrete Corrosion and Durability

Birincil konu Structural Behavior of Reinforced Concrete

Yazarlar

  1. ADEM EMRE CENGİZ KAHRAMANMARAŞ SÜTÇÜ İMAM ÜNİVERSİTESİ
  2. YÜCEL GÜNEY
  3. ONUR KAPLAN
  4. AHMET TOPÇU
  5. YUNUS ÖZÇELİKÖRS
  6. ERK EKİN