Makale detayı · 2012
Structural Defects of Existing RC Buildings in Eskisehir Province
Applied Mechanics and Materials
- Yıl
- 2012
- ISSN
1662-7482- Tür
- article
Veri kaynağı ayrımı
- YÖKSİS YÖKSİS makale kaydı
- OpenAlex OpenAlex zenginleştirmesi (özet, atıf, konular)
Özet
İngilizce (OpenAlex)
In this study, structural defects of existing 709 reinforced concrete (RC) buildings in Eskisehir Province were represented. Structural defects such as gaps between adjacent buildings, strong beam-weak column, mezzanine floor, short column, corner column, discontinuous frame, anchorage beams, long span, segregation, corrosion, inconvenient column/beam lateral reinforcement, low concrete strength and inconvenient steel reinforcement were determined in the study. It was determined that %35 of existing buildings have discontinuous frame, %16 of them have long span problem. It was also observed that nearly %40 of the buildings have no column/beam lateral reinforcement and %70 of them have inadequate gaps.
Konular
- Structural Behavior of Reinforced Concrete
- Structural Load-Bearing Analysis
- Concrete Corrosion and Durability
Birincil konu Structural Behavior of Reinforced Concrete