Comparison of Biomechanical Effects of Different Configurations of Kirschner Wires on the Epiphyseal Plate and Stability in a Salter-Harris Type 2 Distal Femoral Fracture Model

YÖKSİS OpenAlex
Yıl2019
Atıf16OpenAlex
Yüzdelik%81,4
FWCI1,471,00 = dünya ortalaması
Scopus (SJR)Q3
WoS (JCR)Q4

Veri kaynağı ayrımı

  • YÖKSİSYÖKSİS makale kaydı
  • YÖKSİS dergi adıJournal of the American Podiatric Medical Association
  • Katalog eşleşmesi (ISSN)Journal of the American Podiatric Medical Association
  • OpenAlexOpenAlex zenginleştirmesi (özet, atıf, konular)
  • Semantic Scholaratıf sayısı (OpenAlex ile birleştirilmez)

Özet

OpenAlex İngilizce

BACKGROUND: We sought to investigate the different configurations of Kirschner wires used in distal femur Salter-Harris (SH) type 2 epiphyseal fracture for stabilization after reduction under axial, rotational, and bending forces and to define the biomechanical effects on the epiphyseal plate and the fracture line and decide which was more advantageous. METHODS: The SH type 2 fracture was modeled using design software for four different configurations: cross, cross-parallel, parallel medial, and parallel lateral with two Kirschner wires, and computer-aided numerical analyses of the different configurations after reduction were performed using the finite element method. For each configuration, the mesh process, loading condition (axial, bending, and rotational), boundary conditions, and material models were applied in finite element software, and growth cartilage and von Mises stress values occurring around the Kirschner wire groove were calculated. RESULTS: In growth cartilage, the stresses were highest in the parallel lateral configuration and lowest in the cross configuration. In Kirschner wires, the stresses were highest in the cross configuration and lowest in the cross-parallel and parallel lateral configurations. In the groove between the growth cartilage and the Kirschner wire interface, the stresses were highest in the parallel lateral configuration and lowest in the cross configuration. CONCLUSIONS: The results showed that the cross configuration is advantageous in fixation. In addition, in the SH type 2 epiphyseal fracture, we believe that the fixation shape should not be applied in the lateral configuration.

Konular

Atıflar

OpenAlex cited_by_count. WoS veya Scopus atıf sayısı değildir; o kaynaklar için ayrı kolon yoktur.

16atıfOpenAlex · cited_by_count (önbellek / veritabanı)

Yerel katalogda bu makaleye atıf yapan 5 yayın (OpenAlex referans eşleşmesi; tam dünya listesi değildir).

  1. 2022 Comparison of two coracoid process transfer techniques on stress shielding using three-dimensional finite-element modelAtıf 4 · OpenAlex
  2. 2024 Comparison of antegrade and retrograde cross pin fixation in the surgical treatment of pediatric supracondylar femur fractures: A biomechanical studyAtıf 3 · OpenAlex
  3. 2022 Design and Finite Element Analysis of a New Kirschner Wire for Fixing Bone Fractures in Orthopedic SurgeryAtıf 0 · OpenAlex
  4. 2021 The biomechanical comparison of screw fixation and cross pinning methods in salter harris type 2 distal femoral fractures using the finite element methodAtıf 0 · OpenAlex
  5. 2021 The biomechanical comparison of screw fixation and cross pinning methods in salter harris type 2 distal femoral fractures using the finite element methodAtıf 0 · OpenAlex

Yazarlar

5
  1. SERMET İNAL İZMİR BAKIRÇAY ÜNİVERSİTESİ 1
  2. KADİR GÖK 2
  3. ARİF GÖK 3
  4. AHMET MURAT PINAR 4
  5. CANAN İNAL 5