İçeriğe geç
akaturk Akademik ölçüm

Makale detayı · 2015 · article

An Attempt on Methemoglobinemia It s Treatment and Relationship between Treatment and Cerebral Oximeter Value Case Presentation

Dergi International Journal of Clinical Medicine
ISSN2158-284X
YÖKSİS OpenAlex Açık erişim · diamond
Yıl2015
Atıf3OpenAlex
Yüzdelik%12,4
FWCI0,01,00 = dünya ortalaması

Veri kaynağı ayrımı

  • YÖKSİSYÖKSİS makale kaydı
  • YÖKSİS dergi adıInternational Journal of Clinical Medicine
  • OpenAlexOpenAlex zenginleştirmesi (özet, atıf, konular)
  • Semantic Scholaratıf sayısı (OpenAlex ile birleştirilmez)

Özet

OpenAlex İngilizce

Background: Our paper aimed to investigate whether there was a correlation among the pulse oximetry, cerebral oximetry (CO) and MetHb (methemoglobin) values of a patient with congenital methemoglobinemia who underwent a laparoscopic cholecystectomy operation. Case: The 35-year-old male patient with a weight of 70 kg, body massindex (BMI) of 21, American Society of Anesthesia status-2(ASA-2) category who was planned for laparoscopic cholecystectomy operation was identified to have been diagnosed with congenital methemoglobinemia as per his medical history was methemoglobin levels ranged between 12% and 20% according to the periodical measurements taken for the past 3 years. The patient received standard monitoring during anesthesia and device monitoring with a cerebral oximeter (Invos 5100C somatic/cerebral oximeter, Covidien) and a CO-oximetry (Rad ?87 “Rainbow”, Masimo Inc., Irvine, CA) device to continuously follow up his MetHb values was also added. During the intra-operative follow-up, the patient’s methemoglobin level rose to 16%, his peripheral oxygen saturation levels decreased to 86% and his cerebral oximetry values were identified to have also decreased; therefore, methylene blue (MB) was intravenously administered to the patient. The patient continued to be followed up in the post-operative period and he did not develop any complications. Discussion: Appropriate treatment and monitoring enabled the prevention of potential complications. We believe that monitoring with NIRS and MASIMO CO-oximetry device will enable physicians to perform a safe follow-up and treatment in the intraoperative and postoperative follow-up of methemoglobinemia patients.

Konular

Atıflar

OpenAlex cited_by_count. WoS veya Scopus atıf sayısı değildir; o kaynaklar için ayrı kolon yoktur.

3atıfOpenAlex · cited_by_count (önbellek / veritabanı)

Yerel katalogda bu makaleye atıf yapan 3 yayın (OpenAlex referans eşleşmesi; tam dünya listesi değildir).

  1. 2019 Completion Of Septoplasty Operation Despite Decreased Oxygen Saturation In A Patient With Rainier Hemoglobinopathy With General AnesthesiaAtıf 0 · OpenAlex
  2. 2019 Completion Of Septoplasty Operation Despite Decreased Oxygen Saturation In A Patient With Rainier Hemoglobinopathy With General AnesthesiaAtıf 0 · OpenAlex
  3. 2019 Completion Of Septoplasty Operation Despite Decreased Oxygen Saturation In A Patient With Rainier Hemoglobinopathy With General AnesthesiaAtıf 0 · OpenAlex

Yazarlar

5
  1. İLKNUR SUİDİYE YORULMAZ 1
  2. ONUR ÖZLÜ 2
  3. YAVUZ DEMİRARAN 3
  4. GÜLBİN SEZEN 4
  5. ERTAY BORAN DÜZCE ÜNİVERSİTESİ 5