Comparison of the StaRRsed Interliner device with Westergren method in erythrocyte sedimentation rate measurement

YÖKSİS OpenAlex
Yıl2021
Atıf3OpenAlex
Atıf3Semantic Scholar · 1 etkili
Yüzdelik%59,0
FWCI0,391,00 = dünya ortalaması
Scopus (SJR)Q2
WoS (JCR)Q3

Veri kaynağı ayrımı

  • YÖKSİSYÖKSİS makale kaydı
  • YÖKSİS dergi adıInternational Journal of Laboratory Hematology
  • Katalog eşleşmesi (ISSN)International Journal of Laboratory Hematology
  • OpenAlexOpenAlex zenginleştirmesi (özet, atıf, konular)
  • Semantic Scholaratıf sayısı (OpenAlex ile birleştirilmez)

Özet

OpenAlex İngilizce

INTRODUCTION: With recent advances in technology, many manual tests are being replaced by automated devices due to a wide range of advantages. One of these tests is the erythrocyte sedimentation rate (ESR) test that is used to determine inflammatory activity. This study aimed to evaluate the agreement between the Starrsed Interliner sedimentation device and the gold standard method, that is the Westergren method, used in ESR measurement. METHODS: One hundred fifty-one patients who presented to Gaziantep University Faculty of Medicine, Şahinbey Training and Research Hospital were included in this study. ESR values were measured simultaneously within 2 hours using the ESR analyzer Starrsed Interliner device and the gold standard method of measuring ESR, that is the Westergren method, from blood samples collected from the same patients in EDTA and citrate tubes. RESULTS: Agreement between the results from the Starrsed Interliner device and the Westergren method was evaluated using the Intraclass Correlation method. Consequently, a poor correlation was observed at values <20 mm/h, a moderate correlation was observed at values 20 to 80 mm/h and >80 mm/h, and an excellent correlation was observed when all results were considered. Method comparison was conducted according to the Passing-Bablok regression analysis (y = -1.50 + 0.75x) (P < .0001). The mean difference between the two methods was 10.1 according to the Bland-Altman analysis. CONCLUSIONS: Despite the advantages of the Starrsed Interliner device, such as lower laboratory workloads, lower costs and turnaround time, the difference between the two methods, as found in this study, may lead to different clinical interpretations for results in some patient.

Konular

Atıflar

OpenAlex cited_by_count. WoS veya Scopus atıf sayısı değildir; o kaynaklar için ayrı kolon yoktur.

3atıfOpenAlex · cited_by_count (önbellek / veritabanı)

Yerel katalogda bu makaleye atıf yapan 4 yayın (OpenAlex referans eşleşmesi; tam dünya listesi değildir).

  1. 2023 The effect of different anti-inflammatory treatment strategies on process of atherosclerosis in ankylosing spondylitis patientsAtıf 1 · OpenAlex
  2. 2023 The effect of different anti-inflammatory treatment strategies on process of atherosclerosis in ankylosing spondylitis patientsAtıf 1 · OpenAlex
  3. 2023 The effect of different anti-inflammatory treatment strategies on process of atherosclerosis in ankylosing spondylitis patientsAtıf 1 · OpenAlex
  4. 2023 The effect of different anti-inflammatory treatment strategies on process of atherosclerosis in ankylosing spondylitis patientsAtıf 1 · OpenAlex

Yazarlar

4
  1. MUSTAFA ÖRKMEZ 1
  2. SEREN ORHAN 2
  3. MEHMET AKİF BOZDAYI 3
  4. MEHMET TARAKÇIOĞLU GAZİANTEP ÜNİVERSİTESİ 4