Makale detayı · 2024 · article
Application of eco‐friendly disposable pencil graphite sensor for electrochemical evaluation and determination of podophyllotoxin using in cancer treatment
Veri kaynağı ayrımı
- YÖKSİSYÖKSİS makale kaydı
- YÖKSİS dergi adıChemistrySelect
- Katalog eşleşmesi (ISSN)ChemistrySelect
- OpenAlexOpenAlex zenginleştirmesi (özet, atıf, konular)
- Semantic Scholaratıf sayısı (OpenAlex ile birleştirilmez)
Özet
Abstract A sensitive, simple and selective voltammetric method was developed for the quantification of plant‐derived podophyllotoxin, which is included in antineoplastic drugs, using a disposable pencil graphite electrode. Using the square‐wave voltammetry technique, podophyllotoxin gave a very good voltammetric response at +1.24 V (vs. Ag/AgCl) potential (at 0.0 V and after 60 s pre‐concentration) in Britton Robinson (pH 4.0) media. This procedure was used to detection the compound in the concentration range of 12.4–299.5 nM with a limit of detection to 2.62 nM (1.08 μg L −1 ). The proposed method has been successfully applied to human urine samples.
Konular
Atıflar
OpenAlex cited_by_count. WoS veya Scopus atıf sayısı değildir; o kaynaklar için ayrı kolon yoktur.
7atıfOpenAlex · cited_by_count (önbellek / veritabanı)
Yerel katalogda bu makaleye atıf yapan 8 yayın (OpenAlex referans eşleşmesi; tam dünya listesi değildir).
- 2025 A review: electrochemical analysis and application of anticancer drugs with MIP-based sensors and nanosensorsAtıf 13 · OpenAlex
- 2025 A review: electrochemical analysis and application of anticancer drugs with MIP-based sensors and nanosensorsAtıf 13 · OpenAlex
- 2024 Green Voltammetric Detection of Ophthalmic Drug Nepafenac Using Pencil Graphite Electrode as a Responsive Disposable Electrochemical SensorAtıf 7 · OpenAlex
- 2026 Electrochemical and spectrophotometric investigation of DNA interactions with TURKOVAC and Pfizer-BioNTech vaccines: Implications for biosensor sensitivityAtıf 3 · OpenAlex
- 2026 Electrochemical and Spectrophotometric Investigation of DNA Interactions with TURKOVAC and Pfizer-BioNTech Vaccines: Implications for Biosensor SensitivityAtıf 3 · OpenAlex
- 2025 Investigation of electrochemical properties and detection of the antiarrhythmic drug amiodarone in pharmaceutical and urine samples using a disposable pencil graphite electrodeAtıf 2 · OpenAlex
- 2026 Electrochemical investigation and voltammetric determination of the antibody–drug conjugate brentuximab vedotin using an electrochemically activated boron-doped diamond electrodeAtıf 1 · OpenAlex
- 2026 Electrochemical investigation and voltammetric determination of the antibody–drug conjugate brentuximab vedotin using an electrochemically activated boron-doped diamond electrodeAtıf 1 · OpenAlex