Marginal gap of printed, milled, and heat‐pressed two‐piece polyetheretherketone abutments before and after thermal cycling, and their pull‐off bond strength after thermal cycling

Journal of Prosthodontics

YÖKSİS OpenAlex Açık erişim · hybrid SJR Q1 Atıf 6 Üst %10 Yüzdelik 95.1% FWCI 4.9
Yıl
2025
ISSN
1059-941X
Tür
article

Veri kaynağı ayrımı

  • YÖKSİS YÖKSİS makale kaydı
  • OpenAlex OpenAlex zenginleştirmesi (özet, atıf, konular)

Özet

İngilizce (OpenAlex)

PURPOSE: To evaluate the marginal gap of two-piece polyetheretherketone (PEEK) abutments fabricated with different methods, before and after thermal cycling, while also focusing on their pull-off bond strength. MATERIALS AND METHODS: A two-piece abutment was virtually designed after digitizing a titanium-base (Ti-base) abutment. This design was used to fabricate printed (P-PEEK), milled (M-PEEK), and heat-pressed (HP-PEEK) PEEK abutments (n = 8). The marginal gaps of all abutments were evaluated under a stereomicroscope (15 points on each side, ×40 magnification), before and after thermal cycling (10,000 cycles, 5°C-55°C). Then, all abutments were subjected to a pull-off bond strength test. The marginal gap data were analyzed with a generalized linear model, while the pull-off bond strength data were analyzed with one-way analysis of variance and Tukey tests (α = 0.05). RESULTS: The marginal gaps were affected by the interaction between the fabrication method and aging condition, as well as by the fabrication method and aging condition (p ≤ 0.003). HP-PEEK abutments before thermal cycling had the lowest gap, whereas M-PEEK abutments after thermal cycling mostly had the highest (p ≤ 0.042). Thermal cycling increased the marginal gap of HP-PEEK (p < 0.001). M-PEEK had the lowest and HP-PEEK had the highest pull-off bond strength (p < 0.001). Most of the failures of P-PEEK and M-PEEK abutments were mixed. CONCLUSIONS: The tested abutments had marginal gaps below the clinically acceptable threshold of 120 µm, both before and after thermal cycling. HP-PEEK abutments may be more resistant to dislodgment from the Ti-base abutments than P-PEEK and M-PEEK abutments.

Konular

  • Dental materials and restorations
  • Orthopaedic implants and arthroplasty
  • Dental Implant Techniques and Outcomes

Birincil konu Dental materials and restorations

Yazarlar

  1. ALMİRA ADA DİKEN TÜRKSAYAR BİRUNİ ÜNİVERSİTESİ
  2. BURCU KANPALTA
  3. NAİME BİLİNÇ BULUCU
  4. SANDRA PETERSMANN
  5. SEBASTIAN SPINTZYK
  6. MÜNİR DEMİREL BİRUNİ ÜNİVERSİTESİ
  7. MUSTAFA BORGA DÖNMEZ