İçeriğe geç
akaturk Akademik ölçüm

Makale detayı · 2025

Toxicological Assessment of Melamine‐Functionalized Graphene Oxide and Carbon Nanotubes Using Zebrafish Models

Journal of Applied Toxicology

YÖKSİS OpenAlex ISSN 0260-437X DOI 10.1002/jat.4953 Atıf 2 SJR Q2 JCR Q2

10.1002/jat.4953

YÖKSİS YÖKSİS makale kaydı

OpenAlex OpenAlex zenginleştirmesi (özet, atıf, konular)

Özet

OpenAlex kaydı

İngilizce (OpenAlex)

Graphene oxide (GO) and carbon nanotube (CNT)-based nanomaterials have attracted significant interest in various industrial and biomedical applications due to their unique physicochemical properties; however, concerns about their potential toxicity, especially when modified with additives like melamine (M), remain largely unresolved. This study investigates the toxicological effects and underlying mechanisms of graphene oxide-melamine (GO-M) and carbon nanotube-melamine (CNT-M) nanoparticles in zebrafish (Danio rerio) embryos and larvae. To this end, developmental toxicity, phenotypic and behavioral changes, as well as histopathological and immunofluorescence alterations, were evaluated following acute exposure to GO-M and CNT-M nanoparticles at concentrations of 5, 10, and 20 mg/L. Results showed that both nanoparticles delayed larval hatching, particularly at higher concentrations (10 and 20 mg/L). Malformations were observed at 20 mg/L in the GO-M group and at 10 and 20 mg/L in the CNT-M group. Additionally, significant changes in larval length and eye area were observed at all concentrations for both nanoparticles. Behavioral assessments revealed that CNT-M exposure at 10 and 20 mg/L significantly impaired head sensorimotor reflexes, while all concentrations affected tail reflexes. In contrast, GO-M exposure did not significantly alter sensorimotor responses. These findings suggest differential toxic mechanisms and neurobehavioral effects of GO-M and CNT-M nanoparticles during early zebrafish development.

OpenAlex zenginleştirmesi

Konular

  • Graphene and Nanomaterials Applications
  • Nanoparticles: synthesis and applications
  • Carbon and Quantum Dots Applications

Tür: article Graphene and Nanomaterials Applications

İndeks bilgisi

WoS (JCR) ve Scopus (SJR) çeyrekleri ISSN ve yayın yılına göre. · 2025

Scopus (SJR) / WoS (JCR)

Journal of Applied Toxicology

Scopus (SJR) Q2 0,753 2025 yılı
WoS (JCR) Q2 JIF 3,1 2025 yılı

Üniversiteler

  • ORTA DOĞU TEKNİK ÜNİVERSİTESİ

Yazarlar

  1. AYBEK YİĞİT
  2. SERKAN YILDIRIM ORTA DOĞU TEKNİK ÜNİVERSİTESİ
  3. MİNE KÖKTÜRK
  4. Dilek Nazli
  5. METİN KİLİÇLİOĞLU
  6. HATİCE GÜNEŞ ÖZHAN
  7. Begum Celikkiran
  8. GONCA ALAK
  9. MUHAMMED ATAMANALP
  10. NURETTİN MENGEŞ