İçeriğe geç
akaturk Akademik ölçüm

Makale detayı · 2010 · article

Infection Free Titanium Alloys by Stabile Thiol Based Nanocoating

YÖKSİS OpenAlex
Yıl2010
Atıf14OpenAlex
Atıf13Semantic Scholar · 1 etkili
Yüzdelik%69,7
FWCI0,711,00 = dünya ortalaması
Scopus (SJR)Q2
WoS (JCR)Q2

Veri kaynağı ayrımı

  • YÖKSİSYÖKSİS makale kaydı
  • YÖKSİS dergi adıJournal of Nanoscience and Nanotechnology
  • Katalog eşleşmesi (ISSN)Journal of Nanoscience and Nanotechnology (discontinued)
  • OpenAlexOpenAlex zenginleştirmesi (özet, atıf, konular)
  • Semantic Scholaratıf sayısı (OpenAlex ile birleştirilmez)

Özet

OpenAlex İngilizce

As biomedical materials, titanium and titanium alloys (Ti-6Al-4V) are superior to many materials in terms of mechanical properties and biocompatibility. However, they are still not sufficient for prolonged clinical use because the biocompatibility of these materials must be improved. In this study, the prevention of the attachment of test microorganism on the Ti alloy surfaces by thiol (-SH) and hydroxyl (-OH) functional group containing monomer in plasma based electron beam generator was reported in order to prepare anti-fouling surfaces. The precursor, 11-mercaptoundecanoic acid is used as plasma source to create nano-film with 30-60 nm approximately. The surface chemistry and topology of uncoated and coated samples are characterized by Fourier Transform Infrared Spectroscopy (FTIR) and Atomic Force Microscopy (AFM). Static contact angle measurements are performed to state the change of surface hydrophilicity. All coated samples are tested in-vitro environment with Staphylococcus epidermidis that is chosen as the test bacteria strain in view of its significance for the pathogenesis of medical-device-related infections. This test is repeated after certain period of times and samples are waited in dynamic fluid media in order to investigate the stability of nano-coating. Plasma polymerized 11-mercaptoundecanoic acid film (PP MUA) with 42 +/- 4 nm is found alternative, stabile and simple method to create bacterial anti-fouling surfaces. The static contact angle of the coated surface is 34 +/- 80 whereas the uncoated surface is 57 +/- 50. For the coated surface, the presence of C-OH and C==O groups in infrared spectra defining the PP MUA is achieved by the plasma polymerization. The attachment of the model microorganism on the biomaterial surface prepared by PP MUA is reduced 85.3% if compared to unmodified control surface.

Konular

Atıflar

OpenAlex cited_by_count. WoS veya Scopus atıf sayısı değildir; o kaynaklar için ayrı kolon yoktur.

14atıfOpenAlex · cited_by_count (önbellek / veritabanı)

Yerel katalogda bu makaleye atıf yapan 3 yayın (OpenAlex referans eşleşmesi; tam dünya listesi değildir).

  1. 2013 Shielding Efiectiveness of Plasma Coated Multi-layered ShieldsAtıf 2 · OpenAlex
  2. 2014 Improved Bone Formation in Osteoporotic Rabbits with the Bone Morphogenetic Protein-2 (rhBMP-2) Coated Titanium Screws Which Were Coated By Using Plasma Polymerization TechniqueAtıf 0 · OpenAlex
  3. 2014 Improved Bone Formation in Osteoporotic Rabbits with the Bone Morphogenetic Protein-2 (rhBMP-2) Coated Titanium Screws Which Were Coated By Using Plasma Polymerization TechniqueAtıf 0 · OpenAlex

Yazarlar

4
  1. DİLEK ÇÖKELİLER SERDAROĞLU 1
  2. HİLAL GÖKTAŞ ANKARA ÜNİVERSİTESİ 2
  3. PINAR DENİZ TOSUN DÜZCE ÜNİVERSİTESİ 3
  4. SELMA MUTLU 4