İçeriğe geç
akaturk Akademik ölçüm

Makale detayı · 2023 · article

Analytical Validation of a Spiral Microfluidic Chip with Hydrofoil-Shaped Pillars for the Enrichment of Circulating Tumor Cells

Dergi MDPI AG ISSN kaydı başka bir dergiye işaret ediyor; ad YÖKSİS kaydından.
ISSN2079-6374
YÖKSİS OpenAlex Açık erişim · gold
Yıl2023
Atıf6OpenAlex
Yüzdelik%55,6
FWCI0,481,00 = dünya ortalaması
Scopus (SJR)Q1
WoS (JCR)Q1

Veri kaynağı ayrımı

  • YÖKSİSYÖKSİS makale kaydı
  • YÖKSİS dergi adıMDPI AG
  • Katalog eşleşmesi (ISSN)Biosensors
  • OpenAlexOpenAlex zenginleştirmesi (özet, atıf, konular)
  • Semantic Scholaratıf sayısı (OpenAlex ile birleştirilmez)

Özet

OpenAlex İngilizce

The isolation of circulating tumor cells (CTCs) from peripheral blood with high efficiency remains a challenge hindering the utilization of CTC enrichment methods in clinical practice. Here, we propose a microfluidic channel design for the size-based hydrodynamic enrichment of CTCs from blood in an epitope-independent and high-throughput manner. The microfluidic channel comprises a spiral-shaped part followed by a widening part, incorporating successive streamlined pillars, that improves the enrichment efficiency. The design was tested against two benchmark designs, a spiral microfluidic channel and a spiral microfluidic channel followed by a widening channel without the hydrofoils, by processing 5 mL of healthy blood samples spiked with 100 MCF-7 cells. The results proved that the design with hydrofoil-shaped pillars perform significantly better in terms of recovery (recovery rate of 67.9% compared to 23.6% in spiral and 56.7% in spiral with widening section), at a cost of slightly lower white blood cell (WBC) depletion (depletion rate of 94.2% compared to 98.6% in spiral and 94.2% in spiral with widening section), at 1500 µL/min flow rate. For analytical validation, the design was further tested with A549, SKOV-3, and BT-474 cell lines, yielding recovery rates of 62.3 ± 8.4%, 71.0 ± 6.5%, and 82.9 ± 9.9%, respectively. The results are consistent with the size and deformability variation in the respective cell lines, where the increasing size and decreasing deformability affect the recovery rate in a positive manner. The analysis before and after the microfluidic chip process showed that the process does not affect cell viability.

Konular

Atıflar

OpenAlex cited_by_count. WoS veya Scopus atıf sayısı değildir; o kaynaklar için ayrı kolon yoktur.

6atıfOpenAlex · cited_by_count (önbellek / veritabanı)

Yerel katalogda bu makaleye atıf yapan 4 yayın (OpenAlex referans eşleşmesi; tam dünya listesi değildir).

  1. 2026 Evaluation of the Cellsway Microfluidic CTC Enrichment and Identification Platform for CTC Detection in Metastatic NSCLCAtıf 2 · OpenAlex
  2. 2025 Separation of mononuclear cells from progenitor products by a novel inertial microfluidic method.Atıf 2 · OpenAlex
  3. 2025 Separation of mononuclear cells from progenitor products by a novel inertial microfluidic methodAtıf 2 · OpenAlex
  4. 2025 Separation of mononuclear cells from progenitor products by a novel inertial microfluidic methodAtıf 2 · OpenAlex

Yazarlar

11
  1. Begüm Şen Doğan 1
  2. Mehmet Alper Demir 2
  3. Buket Şahin 3
  4. ENDER YILDIRIM 4
  5. Gizem Karayalçın 5
  6. ŞEBNEM İPEK 6
  7. Ege Mutlu 7
  8. TAYLAN BERKIN TORAL 8
  9. Ebru Özgür 9
  10. Özge Zorlu 10
  11. HALUK KÜLAH ORTA DOĞU TEKNİK ÜNİVERSİTESİ 11