İçeriğe geç
akaturk Akademik ölçüm

Makale detayı · 2025 · article

Influence of Preheating Procedure and Polymerization Modes on Degree of Conversion of Contemporary Resin Composites

Dergi Current Research in Dental Sciences
ISSN1300-9044
YÖKSİS OpenAlex Açık erişim · diamond TR Index
Yıl2025
Atıf3OpenAlex
Yüzdelik%84,7
FWCI2,421,00 = dünya ortalaması
Scopus (SJR)Q4

Veri kaynağı ayrımı

  • YÖKSİSYÖKSİS makale kaydı
  • YÖKSİS dergi adıCurrent Research in Dental Sciences
  • OpenAlexOpenAlex zenginleştirmesi (özet, atıf, konular)
  • Semantic Scholaratıf sayısı (OpenAlex ile birleştirilmez)

Özet

OpenAlex İngilizce

Objective: To evaluate the effects of preheating procedure and polymerization modes on degree of conversion (DC) of resin composites. Methods: Three different types of composites - a conventional (GrandioSO - [GSO]), a bulkfill (GrandioSO x-tra - [GSX]), and a thermoviscous bulkfill (VisCalor bulk - [VCB]) - were investigated. Three specimens were prepared for each combination of the variables (composite type*preheating procedure*polymerization mode). Photo-polymerization was performed using an LED operated in standard (SM), high power plus (HM), and x-tra power (XM) modes. DC was measured with Fourier Transform Infrared Spectroscopy after 5 min and 24 h post-irradiation. Furthermore, three-way analysis of variance followed by a Tukey test at a significance level of P <.05 were performed to compare the DC values. Results: Considering the DC values at two post-irradiation time, preheated VCB group polymerized with HM gave the highest DC value, while GSX cured with XM, regardless of the preheating exhibited the lowest one. Preheating application caused a statistically significant increase in the DC values of the VCB*SM, VCB*HM, and GSO*HM groups at both evaluation periods, and the GSX*SM group at 24h post-irradiation. Regarding the polymerization mode, the ranking depending on the significant differences among all preheated composites tested at both time intervals was HM > SM > XM. Conclusion: Preheating generally exhibited favorable effects on the DC of all tested composites, with the most significant impact observed in VCB. Additionally, polymerization with x-tra power mode is not recommended to achieve a sufficient DC required for clinically acceptable restorations. Keywords: bulk fill composite; degree of conversion; FTIR; polymerization mode; preheating; thermoviscousity

Konular

Atıflar

OpenAlex cited_by_count. WoS veya Scopus atıf sayısı değildir; o kaynaklar için ayrı kolon yoktur.

3atıfOpenAlex · cited_by_count (önbellek / veritabanı)

Yerel katalogda bu makaleye atıf yapan 2 yayın (OpenAlex referans eşleşmesi; tam dünya listesi değildir).

  1. 2026 Effect of light-curing modes on degree of conversion and color stability of flowable bulk-fill composites: an in vitro experimental studyAtıf 0 · OpenAlex
  2. 2026 Effect of light-curing modes on degree of conversion and color stability of flowable bulk-fill composites: an in vitro experimental studyAtıf 0 · OpenAlex

Yazarlar

5
  1. ÖZGE GİZEM YENİDÜNYA 1
  2. AHMET ERDEM 2
  3. NİLGÜN AKGÜL PAMUKKALE ÜNİVERSİTESİ 3
  4. BAŞAK YAZKAN 4
  5. MUTLU ÖZCAN 5