Makale detayı · 2023 · article
Mitral Valve Surgery in Patients With an Implanted Amplatzer Septal Occluder: A Review of 2 Cases
Veri kaynağı ayrımı
- YÖKSİSYÖKSİS makale kaydı
- YÖKSİS dergi adıTexas Heart Institute Journal
- Katalog eşleşmesi (ISSN)Texas Heart Institute Journal
- OpenAlexOpenAlex zenginleştirmesi (özet, atıf, konular)
- Semantic Scholaratıf sayısı (OpenAlex ile birleştirilmez)
Özet
Surgical approaches for mitral valve exploration vary, with the preferred approach being via the interatrial groove. Data on whether the interatrial groove approach can be used for mitral valve surgery in patients with a previously implanted Amplatzer septal occluder (ASO) (St Jude Medical, an Abbott company) are extremely limited. The authors performed mitral valve surgery using the transatrial septal approach on 2 patients following explantation of an ASO, which significantly impedes the interatrial groove approach. Concomitant surgical procedures with mitral valve replacement, removal of the ASO, and closure of an atrial septal defect with a patch significantly prolonged the cross-clamp and cardiopulmonary bypass durations, which is the reason for intraoperative low cardiac output syndrome. An intra-aortic balloon pump and venoarterial extra-corporeal membrane oxygenation were used in these 2 patients because of low cardiac output syndrome. When planning mitral valve surgery in patients with a previously implanted ASO, the device precludes the interatrial groove approach and can produce an unpredictable clinical scenario.
Konular
Atıflar
OpenAlex cited_by_count. WoS veya Scopus atıf sayısı değildir; o kaynaklar için ayrı kolon yoktur.
0atıfOpenAlex · cited_by_count (önbellek / veritabanı)