İçeriğe geç
akaturk Akademik ölçüm

Makale detayı · 2015

Effect of 2 chlorhexidine gluconate cavity disinfectant on microtensile bond strength of tooth coloured restorative materials to sound and caries affected dentin

Journal of Adhesion Science and Technology

YÖKSİS OpenAlex SJR Q2 JCR Q3 Atıf 25 Yüzdelik 61.3% FWCI 0.55
Yıl
2015
ISSN
0169-4243
Tür
article

Veri kaynağı ayrımı

  • YÖKSİS YÖKSİS makale kaydı
  • OpenAlex OpenAlex zenginleştirmesi (özet, atıf, konular)

Özet

İngilizce (OpenAlex)

This study evaluated the effect of 2% chlorhexidine gluconate-based cavity disinfectant (CHX) on the microtensile bond strength (μTBS) of glass ionomer, resin-modified glass ionomer and packable resin composite to sound and caries-affected dentin. Sound and occlusal caries-affected human third molars (N = 36, n = 3 per group) were randomly divided into three experimental groups to receive one of the following restorative materials. (a) Glass ionomer (Ketac Molar, 3 M ESPE; GI), (b) resin-modified glass ionomer (Vitremer, 3 M ESPE; RMGI) and (c) packable resin composite (Surefil, Dentsply; PRC) with a bonding agent (Prime Bond NT, Dentsply De Trey). Caries was removed using a caries-detecting dye (Caries Detector, Kuraray Medical Ltd.) and flat dentin surfaces were achieved by finishing up to 1200-grit silicon carbide abrasive. Half of the teeth in each group received 2% CHX (Consepsis, Ultradent). Dentin surfaces were built-up with the respective materials incrementally and were sectioned with a slow-speed saw into multiple beams. The beams were subjected to μTBS test (0.5 mm/min) in a Universal Testing Machine. The data were analysed using two-way analysis of variance and Tukey’s tests. For each restorative material, μTBS results were not affected by the application of CHX (p > 0.05) on both sound and caries-affected dentin (p > 0.05). PRC in combination with the corresponding bonding agent showed significantly higher results (p < 0.05) than those of GI and RMGI, on sound and caries-affected teeth, respectively. Cohesive failure in dentin was not observed in any of the groups. The use of 2% chlorhexidine-based cavity disinfectant did not impair the adhesion of the restorative materials tested to either sound or caries-affected dentin.

Konular

  • Dental materials and restorations
  • Dental Research and COVID-19
  • Endodontics and Root Canal Treatments

Birincil konu Dental materials and restorations

Yazarlar

  1. AykutYetkiner Arzu
  2. Candan Ümit
  3. NAZAN ERSİN EGE ÜNİVERSİTESİ
  4. AHMET CEMAL ERONAT
  5. SEMA BELLİ SELÇUK ÜNİVERSİTESİ
  6. ÖZCAN MUTLU
  7. Melek Merve Panavur