İçeriğe geç
akaturk Akademik ölçüm

Makale detayı · 2014 · article

Corneal wavefront guided customized laser in situ keratomileusis after penetrating keratoplasty

YÖKSİS OpenAlex
Yıl2014
Atıf20OpenAlex
Yüzdelik%81,5
FWCI1,451,00 = dünya ortalaması
Scopus (SJR)Q1
WoS (JCR)Q1

Veri kaynağı ayrımı

  • YÖKSİSYÖKSİS makale kaydı
  • YÖKSİS dergi adıJournal of Cataract & Refractive Surgery
  • Katalog eşleşmesi (ISSN)Journal of Cataract and Refractive Surgery
  • OpenAlexOpenAlex zenginleştirmesi (özet, atıf, konular)
  • Semantic Scholaratıf sayısı (OpenAlex ile birleştirilmez)

Özet

OpenAlex İngilizce

PURPOSE: To assess the efficacy and safety of corneal wavefront-guided custom laser in situ keratomileusis (LASIK) to correct refractive errors and higher-order aberrations (HOAs) after penetrating keratoplasty (PKP). SETTING: Beyoglu Eye Training and Research Hospital, Istanbul, Turkey. DESIGN: Noncomparative case series. METHODS: The study comprised consecutive patients who were unable to tolerate spectacles or contact lenses for the correction of anisometropia after PKP and had corneal wavefront-guided custom LASIK. The uncorrected (UDVA) and corrected (CDVA) distance visual acuities, manifest refraction spherical equivalent (MRSE), and corneal HOAs were recorded before and after LASIK. RESULTS: The study evaluated 11 eyes (10 patients). The mean follow-up after LASIK was 24.3 months ± 11.7 (SD) (range 9 to 36 months). The mean MRSE was -2.97 ± 1.66 diopters (D) (range -0.50 to -5.38 D) preoperatively and -0.88 ± 0.96 D (range -2.75 to 0.5 D) postoperatively. The mean total higher-order root mean square (RMS) was 4.65 ± 1.14 μm (range 2.26 to 5.94 μm) preoperatively and 2.71 ± 1.31 μm (range 1.22 to 5.33 μm) postoperatively. Postoperatively, the UDVA improved in 7 eyes and remained unchanged in 4 eyes. The CDVA improved in all eyes postoperatively even cases in which the attempted astigmatic correction was not totally achieved. CONCLUSIONS: Corneal wavefront-guided custom LASIK after PKP did not totally correct both refractive errors and HOAs because of the high volume of laser ablation required and inadequate corneal stromal thickness.

Konular

Atıflar

OpenAlex cited_by_count. WoS veya Scopus atıf sayısı değildir; o kaynaklar için ayrı kolon yoktur.

20atıfOpenAlex · cited_by_count (önbellek / veritabanı)

Yazarlar

6
  1. SERHAT İMAMOĞLU 1
  2. VEDAT KAYA 2
  3. DENİZ ORAL 3
  4. İRFAN PERENTE 4
  5. BERNA BAŞARIR İSTANBUL SAĞLIK VE TEKNOLOJİ ÜNİVERSİTESİ 5
  6. ÖMER FARUK YILMAZ 6