İçeriğe geç
akaturk Akademik ölçüm

Makale detayı · 2024 · article

Investigation of benzoic acid and sorbic acid concentrations in tomato paste, pepper paste, ketchup, mayonnaise, and barbeque sauce samples by headspace gas chromatography-mass spectrometry

ISSN1300-0527
YÖKSİS OpenAlex Açık erişim · diamond TR Index
Yıl2024
Atıf2OpenAlex
Yüzdelik%39,5
FWCI0,231,00 = dünya ortalaması
Scopus (SJR)Q3
WoS (JCR)Q3

Veri kaynağı ayrımı

  • YÖKSİSYÖKSİS makale kaydı
  • YÖKSİS dergi adıTurkish Journal of Chemistry
  • Katalog eşleşmesi (ISSN)Turkish Journal of Chemistry
  • OpenAlexOpenAlex zenginleştirmesi (özet, atıf, konular)
  • Semantic Scholaratıf sayısı (OpenAlex ile birleştirilmez)

Özet

OpenAlex İngilizce

In this study, it was aimed at investigating benzoic acid (BA) and sorbic acid (SoA) concentrations in tomato paste, pepper paste, ketchup, mayonnaise, and barbeque sauce samples by a validated static headspace gas chromatography-mass spectrometry (GC-MS) method. Salicylic acid (SalA) was used as internal standard and the measurements were conducted in the wide linear concentration ranges of BA and SoA which were 2.5-5000 and 12.5-5000, respectively. The limit of detections (LODs) were determined to be 1.5 and 4.5 mg/kg while the limit of quantifications (LOQs) were 2.5 and 12.5 mg/kg for BA and SoA, respectively. The average recovery% values of BA and SoA were found to be 98.5% and 98.7% in an open tomato paste sample while these values were 98.7% and 100.3% in a mayonnaise sample, respectively. Accuracy of the proposed method was confirmed by statistically (significance test) evaluating excellent recovery values. In real samples, while the results of the canned tomato pastes and industrial sauce samples were found suitable, BA and SoA ​​were determined in some tomato and pepper paste products sold under the traditional or homemade name although use of the preservatives in the pastes were prohibited. It is vital for public health to prevent adulteration in pastes which is indispensable for Turkish cuisine as well as prevalently consumed in the world. Therefore, the proposed method can be used in food control laboratories due to its reliability and consumption of much less toxic chemical reagents.

Konular

Atıflar

OpenAlex cited_by_count. WoS veya Scopus atıf sayısı değildir; o kaynaklar için ayrı kolon yoktur.

2atıfOpenAlex · cited_by_count (önbellek / veritabanı)

Yazarlar

5
  1. HAYRİYE MİNE ANTEP 1
  2. MÜNİRE NALAN DEMİR 2
  3. CEVHER GÜNDOĞDU HIZLIATEŞ DOKUZ EYLÜL ÜNİVERSİTESİ 3
  4. Simge Öztürk 4
  5. Elif ESEN COŞKUN 5