İçeriğe geç
akaturk Akademik ölçüm

Makale detayı · 2018 · article

Added Value of Diffusion-Weighted MR Imaging to Non-Enhanced CT in the Evaluation of Acute Appendicitis

ISSN1735-1065
YÖKSİS OpenAlex Açık erişim · diamond
Yıl2018
Atıf2OpenAlex
Yüzdelik%23,3
FWCI0,01,00 = dünya ortalaması
Scopus (SJR)Q3
WoS (JCR)Q4

Veri kaynağı ayrımı

  • YÖKSİSYÖKSİS makale kaydı
  • YÖKSİS dergi adıIranian Journal of Radiology
  • Katalog eşleşmesi (ISSN)Iranian Journal of Radiology
  • OpenAlexOpenAlex zenginleştirmesi (özet, atıf, konular)
  • Semantic Scholaratıf sayısı (OpenAlex ile birleştirilmez)

Özet

OpenAlex İngilizce

Background: Although non-enhanced CT (NECT) can be applied for the diagnosis of acute appendicitis in obligatory conditions such as impaired renal function, it is not as effective as contrast-enhanced CT. Objectives: This prospective study aims to determine the added value of diffusion weighted imaging (DWI) in the diagnosis of acute appendicitis when combined with non-enhanced computed tomography (NECT). Patients and Methods: Between June 2014 and January 2017, 94 patients (48 male, 46 female) imaged with NECT and DWI for acute appendicitis were enrolled in this prospective study. DWI was obtained with b factors 0, 500 and 1000 s/mm2, and assessed with visual and quantitative analysis. Results of NECT and DWI, and combined imaging (NECT and DWI) were analyzed by means of sensitivity, specificity and accuracy. Results: NECT and DWI provided 91.5% - 94.3% sensitivity, 82.6% - 86.9% specificity and 89.3% - 92.5% accuracy, respectively. The combined protocol (NECT and DWI) revealed 98.5% sensitivity, 95.8% specificity and 97.8% accuracy. The addition of DWI to NECT provided a 7%, 13.2% and 8.5% increase in the sensitivity, specificity and accuracy, respectively. This increase was statistically significant (P < 0.05). Conclusion: DWI is an efficient technique for the diagnosis of acute appendicitis. This even may become more efficient if added to a NECT scan. We recommend using DWI when NECT is inevitable for different reasons. It may increase the diagnostic accuracy of NECT to avoid an additional contrast-enhanced CT scan.

Konular

Atıflar

OpenAlex cited_by_count. WoS veya Scopus atıf sayısı değildir; o kaynaklar için ayrı kolon yoktur.

2atıfOpenAlex · cited_by_count (önbellek / veritabanı)

Yazarlar

6
  1. OĞUZHAN ÖZDEMİR 1
  2. YAVUZ METİN 2
  3. NURGÜL ORHAN METİN 3
  4. ÖZLEM BİLİR 4
  5. ÖZCAN YAVAŞİ RECEP TAYYİP ERDOĞAN ÜNİVERSİTESİ 5
  6. ALİ KÜPELİ 6